- #Error c3451 konica minolta bizhub 282 manual#
- #Error c3451 konica minolta bizhub 282 full#
- #Error c3451 konica minolta bizhub 282 Pc#
The Scanner Home Position Sensor (PC10) does not go from HIGH to LOW when the Scanner Motor M5 is energized for a given number of steps alter the sequence to bring the Scanner back to its home position has been started at the end of a scan motion and during re-shading. The temperature detected by the Fusing Roller Sub Thermistor remains higher than 240☌ for a given period of time. The temperature detected by the Fusing Roller Subthermistor remains lower than 105 оС for a given period of time during a print cycle.įusing failure (abnormally high fusing temperature 2). The temperature detected by the Fusing Roller Sub thermistor remains lower than 105 оС for a given period of time during the standby state. The temperature detected by the Fusing Roller Thermistor remains lower than 12O оС (105 оС for the model having two Fusing Roller Heater Lamps) for a given period of time during a print cycle.įusing failure (abnormally low fusing temperature 2). The temperature detected by the Fusing Roller Thermistor remains lower than 120 оС (105 оС for the model having two Fusing Roller Heater Lamps) for a given period of time during the standby state. after a warm-up cycle has been started and thus the warm-up cycle is not completed.įusing failure (abnormally low fusing temperature) The Fusing Roller Sub Thermistor does not detect a predetermined temperature within 30 sec. Warm-up failure 2 (for the model having two Fusing Roller Heater Lamps) after a warm-up cycle has been started and thus the warm-up cycle is not completed. The Fusing Roller Thermistor does not detect a predetermined temperature within 30 sec. Warm-up failure (for the model having two Fusing Roller Heater Lamps) The surface temperature of the Fusing Roller does not reach a given level even after the lapse of a given period of time during a warm-up cycle.įrom 140 оС to to the completion of the warm-up cycle:. "Model Setting" of "Adjust" available from the Service mode is incorrectly set. #Error c3451 konica minolta bizhub 282 Pc#
The image transfer voltage remains more than 100V continuously for a given period of time while the PC Drum remains stationary.period while the Toner Bottle is turning. The Toner Bottle Home Position Sensor (PC7) outputs a LOW signal for a continuous 2-sec.The Toner Bottle Home Position Sensor (PC7) outputs HIGH signal for a continuous 3.5-sec.period while the Power Supply Cooling Fan Motor Remote signal remains ON (for full-speed rotation) or OFF (for decelerated-speed rotation). The Power Supply Cooling Fan Motor (M4) Lock signal remains HIGH for a continuous 1-sec.Power Supply Cooling Fan Motor malfunction
#Error c3451 konica minolta bizhub 282 full#
period while the Fusing Cooling Fan Motor is turning at full speed or decelerated speed.
The Fusing Cooling Fan Motor (M3) Lock signal HIGH for a continuous 1 -sec. #Error c3451 konica minolta bizhub 282 manual#
Refer to the option service manual (AFR-19) for details.after the Main Motor has started turning.ĪDF Cooling Fan Failure (Only when the optional AFR-19 is mounted) The Main Motor (M1) Lock signal remains HIGH for a continuous 1-sec.